CT1 ? CT2 ? CT6 電流探頭

數(shù)量(件) 價格
100 9629.00元/件
  • 最小起訂: 1件
  • 發(fā)貨地址: 廣東 深圳市
  • 發(fā)布日期:2023-09-22
  • 訪問量:318
咨詢電話:186-6590-2878
打電話時請告知是在機電之家網(wǎng)上看到獲取更多優(yōu)惠。謝謝!
5

深圳市匯馳恒達科技有限公司

實名認證 企業(yè)認證
  • 聯(lián)系人:陳維
  • 手機:18665902878
  • 電話:0755-89399391
  • 營業(yè)執(zhí)照:已審核 營業(yè)執(zhí)照
  • 經(jīng)營模式: 代理商-私營獨資企業(yè)
  • 所在地區(qū):廣東 深圳市
  • 家家通積分:0分
詳細參數(shù)
品牌泰克型號CT1,CT2,CT6電流探頭
加工定制

產(chǎn)品詳情

CT1 ? CT2 ? CT6 電流探頭


Features & Benefits

  • High Bandb
  • Ultra-low Inductance
  • Very Small Form Factor
  • Characterize Current Wavebs up to
  • Very Low Loading of Circuit Under Test
  • Fits Into Dense, Closely-spaced Circuit Designs

Applications

  • Data Storage Read Channel Design
  • Silicon Characterization
  • High-frequency Analog Design
  • ESD Testing
  • Signal Injection
  • Differential Current Measurements
  • Single-shot Low Rep-rate Pulse Measurements
  • Propagation Delay Measurement

CT6 Current Probe

The CT6 is the newest addition to the Tektronix portfolio of high-frequency current probes. It is designed to meet the needs of high-speed circuit design and test applications which require ultra-high bandb, low inductance, and extremely small b factor. The CT6 provides up to 2 GHz bandb when used with high-bandb oscilloscopes such as the Tektronix TDS694C, TDS794D, and TDS7000 Series oscilloscopes or with other compatible 50 Ω b measuring instruments. Low inductance (

CT1/CT2 Current Probes

The CT1 and CT2 Current Probes are designed for permanent or semi-permanent in-circuit installation. Each probe consists of a current transber and an interconnecting cable. The current transbers have a small hole through which a current carrying conductor is passed during circuit assembly.

The P6041 Probe Cable provides the connection between the CT1 and CT2 Current Transbers and a BNC oscilloscope b. A 50 Ω termination is required to terminate the cable when connected to a high-impedance (1 MΩ) oscilloscope b. One probe cable can be used to monitor several current transbers that have been wired into a circuit.


CT1/CT2. Current Probes with P6041 BNC Probe Cable.

Miniature Construction

The CT1 and CT2 detachable cable design enables one or more probes to be located on circuit boards or in other limited space areas.

The CT6 offers the smallest b factor available, for measurement on ever-shrinking circuit boards and components. It is designed for temporary installation and does not incorporate removable cables, as the CT1 and CT2 do.

Extendible Probe Length

Specified rise time and bandb are obtained when using the probe cables provided: The P6041 cable used with the CT1 and CT2 is 42 inches nominal. If additional length is required, the cables can be extended by using high-quality 50 Ω cable and suitable interface connectors. (Also see Special Probe Cables, Optional Accessories.) Long cables may degrade high-frequency response.

High Sensitivity

The CT1 and CT6 provide an output of 5 mV for each milliamp of b current when terminated in 50 Ω. The CT2 provides 1 mV per milliamp when terminated in 50 Ω.

Typical Systems

The CT1, CT2, and CT6 high-frequency current transbers are dynamic (i.e., non-DC) current measuring devices. They are typically used in conjunction with compatible high-bandb oscilloscopes and other instruments to observe and/or record high-frequency current wavebs. The CT1, CT2, and CT6 normally operate directly into 50 Ω scopes and other measuring device bs.

The CT1 or CT2 can be used with 1 MΩ b systems; use the P6041 probe cable and terminate the output with a 50 Ω feed-through termination (see Optional Accessories).

In all cases, the CT1, CT2, and CT6 must work into 50 Ωs to obtain specified perbance and sensitivity.

Typical Measurement Applications

Differential Current Measurements

Most true-differential voltage amplifiers have a maximum bandb of about 100 MHz. The CT1 or CT6 can make differential current measurements to 1 GHz and 2 GHz, respectively, by passing two wires carrying opposing currents through the same core. The displayed result is the difference current. The CT2 can perb the same function to 200 MHz.

In all cases, Derating with Frequency and Amp-second Product (Current-time Product) guidelines should not be exceeded. (See Characteristics.)

Single-shot and Low Rep-rate Pulse Measurements

These common measurements are easy to make with the CT1, CT2, or CT6 provided that your signal fits within the Max Pulse Current and Amp-second Product (Current-time Product) guidelines for the specific current probe characteristics.

For example, the CT2 is rated at 36 A peak, with an Amp-second Product of 50 × 10-6 seconds (50 Amp-microseconds), therefore the CT2 can safely handle a 36 A peak pulse with a maximum b of 1.39 microseconds or lower amplitude pulses for longer pulse bs. The CT1, CT2, and CT6 all have low-frequency roll-off characteristics. Low-frequency "droop" will exhibit itself when the pulse b approaches the L/R time constant of the specific transber.

Propagation Delay Measurements

Two CT1 or CT2 Current Transbers with matching probe cables can be used to measure propagation delay (transit time) between the b and output currents of high-frequency devices. The probe outputs are connected to the bs of dual-channel real-time or sampling scopes.

Verification of any Probe/Cable/Scope System mismatch can be obtained by passing the same signal current through both probes and observing total system delay difference, if any.






溫馨提示

  • 還沒找到想要的產(chǎn)品嗎? 立即發(fā)布采購信息,讓供應(yīng)商主動與您聯(lián)系!

免責聲明:所展示的信息由會員自行提供,內(nèi)容的真實性、準確性和合法性由發(fā)布會員負責,機電之家網(wǎng)對此不承擔任何責任。機電之家網(wǎng)不涉及用戶間因交易而產(chǎn)生的法律關(guān)系及法律糾紛,糾紛由您自行協(xié)商解決。
友情提醒:本網(wǎng)站僅作為用戶尋找交易對象,就貨物和服務(wù)的交易進行協(xié)商,以及獲取各類與貿(mào)易相關(guān)的服務(wù)信息的平臺。為避免產(chǎn)生購買風險,建議您在購買相關(guān)產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。過低的價格、夸張的描述、私人銀行賬戶等都有可能是虛假信息,請采購商謹慎對待,謹防欺詐,對于任何付款行為請您慎重抉擇!如您遇到欺詐等不誠信行為,請您立即與機電之家網(wǎng)聯(lián)系,如查證屬實,機電之家網(wǎng)會對該企業(yè)商鋪做注銷處理,但機電之家網(wǎng)不對您因此造成的損失承擔責任!